yueming co2 laser power supply 60w 80w 100w 150w


Product Description

yueming co2 laser power supply 60w 80w 100w 150w

60w 80w

 

1

Input

AC185V~AC250V

For 60W laser tube output 26mA;

 

 

AC200V~AC250V

For 80W laser tube output 26mA;

2

 

47Hz~100Hz

For 80W laser tube output 26mA

3

 

26mA±1mA

AC220V/50 Hz For 80W laser tube output 26mA

4

Work temperature and Humidity

Work temperature(-10~40)℃ ,comparative Humidity:≤90%

5

Temperature and Humidity

-25℃~65℃,10%~95%RH no mist 

6

Input connection

Standard 2 phase, 3 wire , socket.

 

Output connection

High voltage positive is one red wire 14cm

The negative is wire connector polar.

 

Control connection

DB9standard

 

 

Tube foot:1,7---blank,2---WP,3---5V,4---IN,5---G,6---TL,8---12V,9---TH

7

size

L×W×H=284×197×97 (mm)

8

cooling

Forced air

100w  150w

 

 

Input

Input Voltage

AC220V or AC110V(to be specified when placing order)

AC frequency

47—440HZ

Cold Surge Current

≤60A(AC220V Input)

≤30A(AC110 Input)

Current Leakage

≤0.7mA(AC220V Input)

≤0.4mA(AC110V Input)

Output

Maximum Input Voltage

DC 50KV

Maximum Output Current

DC 38mA

Efficiency

≥90%(full load)

Mean Time Between Failure (MTBF)

≥10000H

Response Speed

≤1ms(from the switch Signal is given to the output current up to 90% of the setting current)

Control Interface

TTL level switch control; high or low effective level can be chosen (details refer to the control terminal specification)  

Withstand Voltage

Input-Output, Input-Shell: AC1500V 10mA 60S; Output negative is connected with machine shell.

Protection

can work in open-circuit condition for a short time(Require a good protective earthing and avoid arc between the positive and the machine shell)

Environment

Operating Temperature-10~40°C,Relative Humidity (RH)≤90%

Cooling Way

Force-Air Cooling (FAC)

Dimension

L×W×H=325*240*95(mm)

 