co2 laser power supply 40w 60w 80w 100w 130w 150w
Product Name:
co2 laser power supply 40w 60w 80w 100w 130w 150wModel No.:
40w,60w,80w,100w, 130w 150wPrice:
600-1500Minimum Order:
1
Product Abstract:
40w 60w 80w 100w 130w 150w co2 laser power supply used for co2 laser engrave machine, co2 laser cut machine
- Product Description
co2 laser power supply used for co2 laser engrave machine, co2 laser cut machine
1. Main Features
1) Good compatibility: It can be applicable to 40W and 30W laser tube.
2) Fast response speed and effect.
3) Dramatically lengthen the life of laser.
4) Easy Control: The start and stop of laser can be easily controlled by TTL level. And there are protection switch to test the external water, ventilation, etc.
5) Easy control of laser power: Both 0-5V analog signal and PWM signal can control the laser power.
6) The power supply has open circuit protection: Under the condition of good protective earthing, the power supply can work in open-circuit for a short time, which could avoid the damage of laser power supply because of the bursting of laser tube, thereby enhancing the life of power supply.
7) The power supply can take feedback interface which can be used in closed-loop control and testing the working current of laser.
8) The power supply adds a new function, that is timely scene judging which part is damaged, laser tube or laser power.
9) Application: acrylic sculpture, cut; fabric sculpture, cut; rubber sheet sculpture, cut, etc.
40w co2 laser power supply
Input
Input Voltage
AC220V or AC110V(to be specified when placing order)
AC frequency
47—440HZ
Cold Surge Current
≤60A(AC220V Input)
≤30A(AC110 Input)
Current Leakage
≤0.7mA(AC220V Input)
≤0.4mA(AC110V Input)
Output
Maximum Input Voltage
DC 25KV
Maximum Output Current
DC 20mA
Efficiency
≥90%(full load)
Mean Time Between Failure (MTBF)
≥10000H
Response Speed
≤1ms(from the switch Signal is given to the output current up to 90% of the setting current)
Control Interface
TTL level switch control; high or low effective level can be chosen (details refer to the control terminal specification)
Withstand Voltage
Input-Output, Input-Shell: AC1500V 10mA 60S; Output negative is connected with machine shell.
Protection
can work in open-circuit condition for a short time(Require a good protective earthing and avoid arc between the positive and the machine shell)
Environment
Operating Temperature: -10~40°C),Relative Humidity (RH)≤90%
Cooling Way
Force-Air Cooling (FAC)
Dimension
L×W×H=167*144*97(mm)
60w co2 laser power supply
Input
Input Voltage
AC220V or AC110V(to be specified when placing order)
AC frequency
47—440HZ
Cold Surge Current
≤60A(AC220V Input)
≤30A(AC110 Input)
Current Leakage
≤0.7mA(AC220V Input)
≤0.4mA(AC110V Input)
Output
Maximum Input Voltage
DC 35KV
Maximum Output Current
DC 23mA
Efficiency
≥90%(full load)
Mean Time Between Failure (MTBF)
≥10000H
Response Speed
≤1ms(from the switch Signal is given to the output current up to 90% of the setting current)
Control Interface
TTL level switch control; high or low effective level can be chosen (details refer to the control terminal specification)
Withstand Voltage
Input-Output, Input-Shell: AC1500V 10mA 60S; Output negative is connected with machine shell.
Protection
can work in open-circuit condition for a short time(Require a good protective earthing and avoid arc between the positive and the machine shell)
Environment
Operating Temperature-10~40 celsius degree,Relative Humidity (RH)≤90%
Cooling Way
Force-Air Cooling (FAC)
Dimension
L×W×H=207*144*97(mm)
80w co2 laser power supply
Input
Input Voltage
AC220V or AC110V(to be specified when placing order)
AC frequency
47—440HZ
Cold Surge Current
≤60A(AC220V Input)
≤30A(AC110 Input)
Current Leakage
≤0.7MA(AC220V Input)
≤0.4MA(AC110V Input)
Output
Maximum Input Voltage
DC 40KV
Maximum Output Current
DC 28MA
Efficiency
≥90%(full load)
Mean Time Between Failure (MTBF)
≥1000H
Response Speed
≤1ms(from the switch Signal is given to the output current up to 90% of the setting current)
Control Interface
TTL level switch control; high or low effective level can be chosen (details refer to the control terminal specification)
Withstand Voltage
Input-Output, Input-Shell: AC1500V 10MA 60S; Output negative is connected with machine shell.
Protection
can work in open-circuit condition for a short time(Require a good protective earthing and avoid arc between the positive and the machine shell)
Environment
Operating Temperature:-10~40°C,Relative Humidity (RH)≤90%
Cooling Way
Force-Air Cooling (FAC)
Dimension
L×W×H=280*173*97(mm)
100-150w co2 laser power supply
Input
Input Voltage
AC220V or AC110V(to be specified when placing order)
AC frequency
47—440HZ
Cold Surge Current
≤60A(AC220V Input)
≤30A(AC110 Input)
Current Leakage
≤0.7mA(AC220V Input)
≤0.4mA(AC110V Input)
Output
Maximum Input Voltage
DC 50KV
Maximum Output Current
DC 38mA
Efficiency
≥90%(full load)
Mean Time Between Failure (MTBF)
≥10000H
Response Speed
≤1ms(from the switch Signal is given to the output current up to 90% of the setting current)
Control Interface
TTL level switch control; high or low effective level can be chosen (details refer to the control terminal specification)
Withstand Voltage
Input-Output, Input-Shell: AC1500V 10mA 60S; Output negative is connected with machine shell.
Protection
can work in open-circuit condition for a short time(Require a good protective earthing and avoid arc between the positive and the machine shell)
Environment
Operating Temperature-10~40°C,Relative Humidity (RH)≤90%
Cooling Way
Force-Air Cooling (FAC)
Dimension
L×W×H=325*240*95(mm)