Product Abstract:

water cooling co2 laser power meter 0-200w


Product Description
  • Introduction; Our power meter is water currency cooled power meter, it can measure up to 1000w laser with
  •  good water currency. It has big target area,high respond speed ,high accuracy ,good repeating usage 
  • . It use red led screen to show the laser power, it is very convenient to read and necessary in laser lab and factory.  
  • Parameters:
  • testing range:1-1000w
  • Testing accuracy:+/-5%
  • Respond time: within 15seconds
  • Target area diameter:26mm
  • .wave length range:1.06um,10.6um,0.4-10.6um can be measured , have to be set up separately.
  • One time work hour: 24 hours continually with water currency.
  • Damage factors: beam diameter above 5-8mm, 1000w;beam dia below 2mm ,100w;without water currency for 20 seconds.

三:usage direction

  1. press the key on the the panel, the screen will show 0
  2. Put the power meter detector before the output end of the laser, make sure the laser beam goes to the center of the target area.
  3. Put the detector close to the output end, in case the laser beam goes bent.
  4. Read the number on the led screen when the laser goes to the target area, the number on the screen 
  5. may increase , the biggest number is the power of the laser.
  6.  When testing high power laser, try to shorten the testing time, like test 100w laser, can last to the last digit stable. 
  7. 500w when the the second digit from right stable.1000w when the second digit from the right increase slowly
  8.  then several numbers later, stop. In all try to short the testing time in case the detector temperature too high , and damage the power meter.
  9.  Owing to small weight, the detector temperature can increase quickly, we can cool them by air cooling , like fans or wet cloth.,when use wet cloth don't let water on the target area, the power meter can be used again after this.
  10. When the screen shows +, it means the battery is low, please change the battery.
  11. When change the batteries, open the two screws at the bottom of the back cover..then pull the forward cover backward,
  12.  then turn. Then change the batteries is ok. The batteries is 12v. 
  13. Water currency: can have the water currency separately, can also use the same cooling water with the laser, the laser water 
  14. output end connect to the power meter water entrance ,the power meter water output connect to the chiller.
  15. power meter's water end is the same don't have entrance and exit difference.